Neural Regeneration Research ›› 2015, Vol. 10 ›› Issue (1): 79-83.doi: 10.4103/1673-5374.150710

Previous Articles     Next Articles

Use of nerve elongator to repair short-distance peripheral nerve defects: a prospective randomized study

Lu Bai 1, Tian-bing Wang 1, Xin Wang 2, Wei-wen Zhang 2, Ji-hai Xu 2, Xiao-ming Cai 2, Dan-ya Zhou 2, Li-bing Cai 2, Jia-dong Pan 2,Min-tao Tian 2, Hong Chen 2, *, Dian-ying Zhang 1, Zhong-guo Fu 1, Pei-xun Zhang 1, *, Bao-guo Jiang 1, *   

  1. 1 Department of Trauma and Orthopedics, Peking University People’s Hospital, Beijing, China
    2 Department of Hand Surgery, Ningbo No.6 Hospital, Ningbo, Zhejiang Province, China
  • Received:2014-12-11 Online:2015-01-15 Published:2015-01-15
  • Contact: Bao-guo Jiang, M.D.,jiangbaoguo@vip.sina.com. Pei-xun Zhang, M.D., zhangpeixun@126.com. Hong Chen, chenhong_6612@163.com.
  • Supported by:

    This study was supported by grants from the National Natural Science Foundation of China, No. 31171150, 31271284, 81171146, 30971526, 30801169; the National Program on Key Basic Research Project of China (973 Program), No. 2014CB542206; Program for New Star in Science and Technology of Beijing of China, No. A-2008-10; Program for New Century Excellent Talents in University of Ministry of Education of China, No. BMU20110270; and the National Natural Science Foundation of China for Distinguished Youth, No. 31100860.

Abstract:

Repair techniques for short-distance peripheral nerve defects, including adjacent joint flexion to reduce the distance between the nerve stump defects, “nerve splint” suturing, and nerve sleeve connection, have some disadvantages. Therefore, we designed a repair technique involving intraoperative tension-free application of a nerve elongator and obtained good outcomes in the repair of short-distance peripheral nerve defects in a previous animal study. The present study compared the clinical outcomes between the use of this nerve elongator and performance of the conventional method in the repair of short-distance transection injuries in human elbows. The 3-, 6-, and 12-month postoperative follow-up results demonstrated that early neurological function recovery was better in the nerve elongation group than in the conventional group, but no significant difference in long-term neurological function recovery was detected between the two groups. In the nerve elongation group, the nerves were sutured without tension, and the duration of postoperative immobilization of the elbow was decreased. Elbow function rehabilitation was significantly better in the nerve elongation group than in the control group. Moreover, there were no security risks. The results of this study confirm that the use of this nerve elongator for repair of short-distance peripheral nerve defects is safe and effective.

Key words: nerve regeneration, peripheral nerve deficiency, nerve elongator, British Medical Research Council scale, neurological function, prognosis, NSFC grants, neural regeneration